{"id":1796936466467,"title":"SteriTec Steri-Pak Kit LF S\/T Reusable Bowie Dick Type 2 Test Kit","handle":"steri-pak-kit-lf-s-t","description":"\u003cp\u003e\u003cem\u003eOverview\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eType: \u003c\/strong\u003eReusable Bowie Dick Test Kit\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e11140-1, Type 2\u003cbr\u003e \u003cstrong\u003eTemperature:\u003c\/strong\u003e 134°C\u003cbr\u003e \u003cstrong\u003eTime: \u003c\/strong\u003e3.5 minutes\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse for daily monitoring of pre-vacuum steam sterilizers operating at 134°C to detect air leaks, inadequate steam penetration and vacuum pump failures.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#resourcesPDF\" role=\"button\" aria-expanded=\"false\" aria-controls=\"resourcesPDF\"\u003e \u003ci class=\"fa fa-file-pdf-o\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Resources \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"resourcesPDF\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003ca class=\"ti_icon ti_ico_data\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Data-Sheet.pdf\" title=\"datasheet\"\u003e\u003cspan\u003eData Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003ca class=\"ti_icon ti_ico_info\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Interpretation-Guides.pdf\" title=\"Interpretation Guide\"\u003e\u003cspan\u003eInterpretation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\n\u003ca class=\"ti_icon ti_ico_brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Brochure.pdf\" title=\"Brochure\"\u003e\u003cspan\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD_109ST_DF-023-1M_IFU_Sheet.pdf?v=1626267239\" class=\"Hyperlink SCXW21336507 BCX0\" target=\"_blank\"\u003e\u003cspan class=\"TextRun Underlined SCXW21336507 BCX0\" lang=\"EN-US\" data-contrast=\"none\" xml:lang=\"EN-US\"\u003e\u003cspan data-ccp-charstyle=\"Hyperlink\" class=\"NormalTextRun SCXW21336507 BCX0\"\u003eInstructions For Use\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan class=\"TextRun EmptyTextRun SCXW21336507 BCX0\" lang=\"EN-US\" data-contrast=\"auto\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW21336507 BCX0\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003cspan\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW21336507 BCX0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD_109_S-T_FTP-093I-SteriTec-BD109ST-PRS.pdf?v=1626271540\" class=\"Hyperlink SCXW250887526 BCX0\" target=\"_blank\"\u003e\u003cspan class=\"TextRun Underlined SCXW250887526 BCX0\" lang=\"EN-US\" data-contrast=\"none\" xml:lang=\"EN-US\"\u003e\u003cspan data-ccp-charstyle=\"Hyperlink\" class=\"NormalTextRun SCXW250887526 BCX0\"\u003eProduct Specification\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan class=\"TextRun EmptyTextRun SCXW250887526 BCX0\" lang=\"EN-US\" data-contrast=\"auto\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW250887526 BCX0\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#techspec\" role=\"button\" aria-expanded=\"false\" aria-controls=\"techspec\"\u003e\u003ci class=\"fa fa-newspaper-o\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Specification \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"techspec\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_gui_detail\"\u003e\n\u003cstrong\u003eReusable Bowie Dick Indicator\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e 11140-1:2005, Class 2\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e 11140-4:2007\u003cbr\u003e \u003cstrong\u003eColour change: \u003c\/strong\u003eBlue to Black with no air leak.\u003cbr\u003e \u003cstrong\u003eDimensions: \u003c\/strong\u003e14.447cm x 11.43cm (5.6875\" x 4.5\")\u003cbr\u003e \u003cstrong\u003eReaction Time:\u003c\/strong\u003e 3.5 minutes at 134°C (273.2\u003cspan\u003e°\u003c\/span\u003eF)\u003cbr\u003e \u003cstrong\u003eType:\u003c\/strong\u003e Test Pack - 2 sets of blotter cards and 30 indicator sheets.\u003cbr\u003e \u003cstrong\u003eSafety Data: \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-MSDS.pdf\" title=\"Material Safety Data Sheet\"\u003eMaterial Safety Data Sheet\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#proddetails\" role=\"button\" aria-expanded=\"false\" aria-controls=\"proddetails\"\u003e \u003ci class=\"fa fa-info-circle\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Details \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"proddetails\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_gui_desc\"\u003eSteri-Pak Kit LF Sub-Trans Bowie-Dick Test Packs are designed as an environmentally safe lead free method for daily monitoring of pre-vacuum steam sterilizers to detect air leaks, inadequate steam penetration and vacuum pump failures. The Steri-Pak Kit LF Sub-Trans Test Pack is designed to meet the ISO 11140-4 test methods for detecting temperature drops and the presence of air in sub-atmospheric and trans-atmospheric steam sterilization cycles. The test pack is placed in the sterilizer in the most difficult to sterilize area and run through a sterilization cycle for 3.5 minutes at 134°C. If no appreciable air is present in the sterilizer chamber after vacuums are drawn, the steam will penetrate to the middle of the test pack and turn the indicator sheet a uniform black colour. If a small amount of air is present, the centre of the sheet will display a bluish colour rather than a uniform black. Each kit consists of two sets of blotter cards and 30 indicator sheets. One indicator sheet is placed in the middle of a blotter card set to form a test pack. The test pack is then placed in the kit holding frame (REF BD 105) and clamped. Blotter card sets can be used for 15 test runs. The Cover Card has numbers designating each time the set has been tested. The test run number is marked off after each use. \u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved ink chemistry aids interpretation\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eBlue colour remains is air leak is present.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigh Standards\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous ink design from center to edge.\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eMakes air leaks eaier to see\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmentally Safe\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eImproved chemistry is both lead free and toxic heavy metals free\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermanent colour change\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eCan be used as a permanent record when stored away from light sources\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2019-07-09T14:27:57+01:00","created_at":"2019-07-09T14:27:57+01:00","vendor":"Steri-Pak Kit LF S\/T","type":"Steri-Pak Kit LF S\/T","tags":["Medical Device Cleaning and Sterilization","Steri-Pak Kit LF S\/T"],"price":56425,"price_min":56425,"price_max":56425,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":15171458826275,"title":"Steri-Pak Kit LF S\/T Reusable Bowie-Dick Test Packs (16 Packs)","option1":"Steri-Pak Kit LF S\/T Reusable Bowie-Dick Test Packs (16 Packs)","option2":null,"option3":null,"sku":"BD 109\/S-T","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SteriTec Steri-Pak Kit LF S\/T Reusable Bowie Dick Type 2 Test Kit - Steri-Pak Kit LF S\/T Reusable Bowie-Dick Test Packs (16 Packs)","public_title":"Steri-Pak Kit LF S\/T Reusable Bowie-Dick Test Packs (16 Packs)","options":["Steri-Pak Kit LF S\/T Reusable Bowie-Dick Test Packs (16 Packs)"],"price":56425,"weight":7000,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/temperature-indicators.co.uk\/cdn\/shop\/products\/BD109-lrg.jpg?v=1564951281"],"featured_image":"\/\/temperature-indicators.co.uk\/cdn\/shop\/products\/BD109-lrg.jpg?v=1564951281","options":["Options"],"media":[{"alt":null,"id":1762462924835,"position":1,"preview_image":{"aspect_ratio":1.0,"height":360,"width":360,"src":"\/\/temperature-indicators.co.uk\/cdn\/shop\/products\/BD109-lrg.jpg?v=1564951281"},"aspect_ratio":1.0,"height":360,"media_type":"image","src":"\/\/temperature-indicators.co.uk\/cdn\/shop\/products\/BD109-lrg.jpg?v=1564951281","width":360}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cem\u003eOverview\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eType: \u003c\/strong\u003eReusable Bowie Dick Test Kit\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e11140-1, Type 2\u003cbr\u003e \u003cstrong\u003eTemperature:\u003c\/strong\u003e 134°C\u003cbr\u003e \u003cstrong\u003eTime: \u003c\/strong\u003e3.5 minutes\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse for daily monitoring of pre-vacuum steam sterilizers operating at 134°C to detect air leaks, inadequate steam penetration and vacuum pump failures.\u003c\/p\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#resourcesPDF\" role=\"button\" aria-expanded=\"false\" aria-controls=\"resourcesPDF\"\u003e \u003ci class=\"fa fa-file-pdf-o\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Resources \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"resourcesPDF\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003ca class=\"ti_icon ti_ico_data\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Data-Sheet.pdf\" title=\"datasheet\"\u003e\u003cspan\u003eData Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003ca class=\"ti_icon ti_ico_info\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Interpretation-Guides.pdf\" title=\"Interpretation Guide\"\u003e\u003cspan\u003eInterpretation Guide\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\n\u003ca class=\"ti_icon ti_ico_brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-Brochure.pdf\" title=\"Brochure\"\u003e\u003cspan\u003eBrochure\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD_109ST_DF-023-1M_IFU_Sheet.pdf?v=1626267239\" class=\"Hyperlink SCXW21336507 BCX0\" target=\"_blank\"\u003e\u003cspan class=\"TextRun Underlined SCXW21336507 BCX0\" lang=\"EN-US\" data-contrast=\"none\" xml:lang=\"EN-US\"\u003e\u003cspan data-ccp-charstyle=\"Hyperlink\" class=\"NormalTextRun SCXW21336507 BCX0\"\u003eInstructions For Use\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan class=\"TextRun EmptyTextRun SCXW21336507 BCX0\" lang=\"EN-US\" data-contrast=\"auto\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW21336507 BCX0\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ti_prod_icons\"\u003e\u003cspan\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW21336507 BCX0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD_109_S-T_FTP-093I-SteriTec-BD109ST-PRS.pdf?v=1626271540\" class=\"Hyperlink SCXW250887526 BCX0\" target=\"_blank\"\u003e\u003cspan class=\"TextRun Underlined SCXW250887526 BCX0\" lang=\"EN-US\" data-contrast=\"none\" xml:lang=\"EN-US\"\u003e\u003cspan data-ccp-charstyle=\"Hyperlink\" class=\"NormalTextRun SCXW250887526 BCX0\"\u003eProduct Specification\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan class=\"TextRun EmptyTextRun SCXW250887526 BCX0\" lang=\"EN-US\" data-contrast=\"auto\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003e\u003cspan data-ccp-props='{\"201341983\":0,\"335559739\":160,\"335559740\":259}' class=\"EOP SCXW250887526 BCX0\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#techspec\" role=\"button\" aria-expanded=\"false\" aria-controls=\"techspec\"\u003e\u003ci class=\"fa fa-newspaper-o\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Specification \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"techspec\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_gui_detail\"\u003e\n\u003cstrong\u003eReusable Bowie Dick Indicator\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e 11140-1:2005, Class 2\u003cbr\u003e \u003cstrong\u003eISO: \u003c\/strong\u003e 11140-4:2007\u003cbr\u003e \u003cstrong\u003eColour change: \u003c\/strong\u003eBlue to Black with no air leak.\u003cbr\u003e \u003cstrong\u003eDimensions: \u003c\/strong\u003e14.447cm x 11.43cm (5.6875\" x 4.5\")\u003cbr\u003e \u003cstrong\u003eReaction Time:\u003c\/strong\u003e 3.5 minutes at 134°C (273.2\u003cspan\u003e°\u003c\/span\u003eF)\u003cbr\u003e \u003cstrong\u003eType:\u003c\/strong\u003e Test Pack - 2 sets of blotter cards and 30 indicator sheets.\u003cbr\u003e \u003cstrong\u003eSafety Data: \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0023\/1853\/2643\/files\/BD109-MSDS.pdf\" title=\"Material Safety Data Sheet\"\u003eMaterial Safety Data Sheet\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca class=\"btn prodbtn\" data-toggle=\"collapse\" href=\"#proddetails\" role=\"button\" aria-expanded=\"false\" aria-controls=\"proddetails\"\u003e \u003ci class=\"fa fa-info-circle\" aria-hidden=\"true\"\u003e\u003c\/i\u003e Details \u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapse\" id=\"proddetails\"\u003e\n\u003cdiv class=\"card card-body\"\u003e\n\u003cdiv class=\"ti_prod_gui_desc\"\u003eSteri-Pak Kit LF Sub-Trans Bowie-Dick Test Packs are designed as an environmentally safe lead free method for daily monitoring of pre-vacuum steam sterilizers to detect air leaks, inadequate steam penetration and vacuum pump failures. The Steri-Pak Kit LF Sub-Trans Test Pack is designed to meet the ISO 11140-4 test methods for detecting temperature drops and the presence of air in sub-atmospheric and trans-atmospheric steam sterilization cycles. The test pack is placed in the sterilizer in the most difficult to sterilize area and run through a sterilization cycle for 3.5 minutes at 134°C. If no appreciable air is present in the sterilizer chamber after vacuums are drawn, the steam will penetrate to the middle of the test pack and turn the indicator sheet a uniform black colour. If a small amount of air is present, the centre of the sheet will display a bluish colour rather than a uniform black. Each kit consists of two sets of blotter cards and 30 indicator sheets. One indicator sheet is placed in the middle of a blotter card set to form a test pack. The test pack is then placed in the kit holding frame (REF BD 105) and clamped. Blotter card sets can be used for 15 test runs. The Cover Card has numbers designating each time the set has been tested. The test run number is marked off after each use. \u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved ink chemistry aids interpretation\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eBlue colour remains is air leak is present.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigh Standards\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous ink design from center to edge.\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eMakes air leaks eaier to see\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmentally Safe\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eImproved chemistry is both lead free and toxic heavy metals free\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermanent colour change\u003c\/strong\u003e \u003cspan class=\"indent\"\u003eCan be used as a permanent record when stored away from light sources\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

SteriTec Steri-Pak Kit LF S/T Reusable Bowie Dick Type 2 Test Kit

Product Description

Overview

Type: Reusable Bowie Dick Test Kit
ISO: 11140-1, Type 2
Temperature: 134°C
Time: 3.5 minutes

Use for daily monitoring of pre-vacuum steam sterilizers operating at 134°C to detect air leaks, inadequate steam penetration and vacuum pump failures.

Reusable Bowie Dick Indicator
ISO: 11140-1:2005, Class 2
ISO: 11140-4:2007
Colour change: Blue to Black with no air leak.
Dimensions: 14.447cm x 11.43cm (5.6875" x 4.5")
Reaction Time: 3.5 minutes at 134°C (273.2°F)
Type: Test Pack - 2 sets of blotter cards and 30 indicator sheets.
Safety Data: Material Safety Data Sheet

Steri-Pak Kit LF Sub-Trans Bowie-Dick Test Packs are designed as an environmentally safe lead free method for daily monitoring of pre-vacuum steam sterilizers to detect air leaks, inadequate steam penetration and vacuum pump failures. The Steri-Pak Kit LF Sub-Trans Test Pack is designed to meet the ISO 11140-4 test methods for detecting temperature drops and the presence of air in sub-atmospheric and trans-atmospheric steam sterilization cycles. The test pack is placed in the sterilizer in the most difficult to sterilize area and run through a sterilization cycle for 3.5 minutes at 134°C. If no appreciable air is present in the sterilizer chamber after vacuums are drawn, the steam will penetrate to the middle of the test pack and turn the indicator sheet a uniform black colour. If a small amount of air is present, the centre of the sheet will display a bluish colour rather than a uniform black. Each kit consists of two sets of blotter cards and 30 indicator sheets. One indicator sheet is placed in the middle of a blotter card set to form a test pack. The test pack is then placed in the kit holding frame (REF BD 105) and clamped. Blotter card sets can be used for 15 test runs. The Cover Card has numbers designating each time the set has been tested. The test run number is marked off after each use.

  • Improved ink chemistry aids interpretation Blue colour remains is air leak is present.
  • High Standards
  • Continuous ink design from center to edge. Makes air leaks eaier to see
  • Environmentally Safe Improved chemistry is both lead free and toxic heavy metals free
  • Permanent colour change Can be used as a permanent record when stored away from light sources
Sku: BD 109/S-T